For research use only. Not for human or veterinary use. Supplied as a lyophilized powder for laboratory research.
“Third-party tested peptides” means the analytical results on a peptide lot come from a laboratory other than the seller. That separation matters because a certificate is only as useful as the lab behind it. Third-party testing does not mean any particular test was run. Each certificate lists the tests performed, usually chromatographic purity, mass spectrometry identity and sometimes quantity and endotoxin, and each result answers a different question [1][2].
What does third-party tested mean for peptides?
- Who: a testing laboratory independent of the supplier analyzes a sample from the lot.
- What: only the tests named on the report. A purity report does not cover endotoxin, and an identity result does not cover quantity [1][2].
- Which lot: the result applies to the lot number on the report, not to the product name in general.
Which tests a peptide testing lab typically runs
| Test | Question it answers | Limits |
|---|---|---|
| HPLC/UPLC purity | What share of the detected peak area is the main peptide? | Relative and method-dependent [1] |
| Mass spectrometry (MS) | Does the main component have the expected mass? | Identity, not amount; isomers need more work [1] |
| Quantity / net content | How much peptide is in the vial? | Affected by counter-ions and water [3] |
| Endotoxin (BET) | Is bacterial endotoxin within the stated limit? | Separate assay from purity [4] |
Synthetic peptides carry known impurity classes, such as deletion and insertion sequences, diastereomers and oxidation products, that a well-designed purity method is meant to separate [2].
ISO/IEC 17025 and lab competence
ISO/IEC 17025:2017 sets general requirements for the competence of testing and calibration laboratories, and accreditation bodies assess labs against it [5]. Accreditation applies to a specific scope of methods. When a certificate claims accreditation, check that the method used (for example HPLC purity) is within the lab’s accredited scope. Method validation principles for analytical procedures, such as specificity, accuracy and precision, are described in the ICH Q2(R2) guideline [6].
How to check a third-party peptide COA
- Confirm the lab is named and is not the seller.
- Match the lot number on the certificate to the vial.
- Check the analysis date, method and specification next to each result.
- Use the lab’s verification route (QR code or report number) where offered.
- Compare formula and molecular weight with a public record such as PubChem.
MFP’s certificates name the testing laboratory. For example, the BPC-157 and TB-500 (Thymosin Beta-4) certificates are issued by Horizon Analytical, with report numbers and analysis dates, and are listed in the COA Library.
Frequently asked questions
It means an independent lab, not the seller, ran the tests listed on the certificate for that specific lot.
Not by itself. It means a separate lab measured purity (and possibly other properties). Read the actual purity result and method [1].
ISO/IEC 17025 is the international standard for testing-laboratory competence; accreditation against it covers a defined scope of methods [5].
Purity (HPLC/UPLC) and identity (MS) are the core pair. Endotoxin and quantity add information neither one provides [1][3][4].
Research materials and certificates
- COA Library · Shop · FAQ
- Related: How to Verify a Peptide COA · How to Read a Peptide COA
References
- Lian Z, Wang N, Tian Y, Huang L. Characterization of Synthetic Peptide Therapeutics Using Liquid Chromatography-Mass Spectrometry: Challenges, Solutions, Pitfalls, and Future Perspectives. J Am Soc Mass Spectrom. 2021;32(8):1852-1860. doi:10.1021/jasms.0c00479. PMID: 34110145
- D’Hondt M, Bracke N, Taevernier L, et al. Related impurities in peptide medicines. J Pharm Biomed Anal. 2014;101:2-30. doi:10.1016/j.jpba.2014.06.012. PMID: 25044089
- Erckes V, Streuli A, Chamera Rendueles L, Krämer SD, Steuer C. Towards a Consensus for the Analysis and Exchange of TFA as a Counterion in Synthetic Peptides and Its Influence on Membrane Permeation. Pharmaceuticals (Basel). 2025;18(8):1163. doi:10.3390/ph18081163. PMID: 40872554
- Cai T, Pei Y. The bacterial endotoxin test in the Chinese pharmacopoeia: A journey of international harmonization and national consideration. J Microbiol Methods. 2026;242:107411. doi:10.1016/j.mimet.2026.107411. PMID: 41620123
- International Organization for Standardization. ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. iso.org
- U.S. Food and Drug Administration. Q2(R2) Validation of Analytical Procedures (ICH guidance). fda.gov
Research-use-only disclaimer: All products from My Freedom Peptides are supplied as a lyophilized powder for laboratory research. They are for research use only and not for human or veterinary use. My Freedom Peptides LLC is a chemical supplier. It is not a 503A compounding pharmacy or a 503B outsourcing facility. These statements have not been evaluated by the Food and Drug Administration. Products are not intended to diagnose, treat, cure, or prevent any disease.